AS-1 Specifications

Deprecated. Please see the S1n hydrophone, which offers practically identical performance.

The AS-1 utilizes a passive piezo sensing element. There is no preamp or impedance buffer circuit within the hydrophone, which allows it to be used as an omnidirectional projector (transmitter) as well as a receiver. The following specifications were obtained from the average of a limited sample group and were measured at the end of 9-meter cable lengths.

Acoustic performance

Linear range
1 Hz to 100 kHz (±2 dB)
Receiving sensitivity1
-208 dBV re: 1 µPa (40 µV / Pascal)
Transmitting sensitivity
140 dB SPL re: 1 µPa, 1 Vrms input at 1 meter, 90 kHz
Maximum input voltage
30 V p-p (continuous)
150 V p-p (<10% duty cycle, <100 kHz)
Nominal capacitance
5 nF ±15% (plus cable @ 118 pF/m)

Directivity

Horizontal directivity (20 kHz)
±0.2 dB
Horizontal directivity (100 kHz)
±1 dB
Vertical directivity (20 kHz)
±1 dB
Vertical directivity (100 kHz)
+6 dB / -11 dB

1 The AS-1 is not individually calibrated. Standard quality control allows for a ±3 dB deviation of nominal sensitivity plus measurement error with compensation for cable attenuation. Thus, any given AS-1, especially those with longer cable lengths, can deviate from the published specifications.

Physical

Operating depth
200 meters
Survival depth
350 meters
Operating temperature range
-10 °C to +80 °C
Output connection
BNC (standard); bare wire available
Size
Ø12 mm × 40 mm
Weight in air
8 grams (plus cable @ 28 g/m)
Cable length
10 meters standard. Any length on request.
Cable jacket
Polyurethane, 4.5 mm OD
Encapsulant
Polyurethane

 

Select plots

AS-1 hydrophone response charts

NOTES:

Data obtained from US Navy, Underwater Sound Reference Division, Newport, June 2013, measurements taken at end of 9-meter cable.

Calibration

The Aquarian AS-1 hydrophone is not individually calibrated during manufacturing. Instead, it undergoes standard quality control procedures that include nominal sensitivity, capacitance, leak test, and listening test.

We no longer provide additional calibration services through the US Navy Underwater Sound Reference Division. For precise applications requiring detailed calibration data, the customer must arrange their own calibration.