The H3 has three distinctly different specifications depending on configuration and use. Raw sensor output, and integrated electronics when powered by plug-in power circuits or phantom power circuits.
In all cases, the output impedance of the H3 is set by circuit with which the hydrophone is used. This also means that there is no fixed gain, frequency response, or bandwidth across all devices and use cases. Therefore we do not publish detailed response plots for this design, and offer the following specifications with caveats of the specific conditions there were derived.
Raw Sensor Output (H3n)
The following specifications are based on typical response when the hydrophone is driving a high-impedance input:- Sensitivity
- -192 dB re: 1V/µPa (+/- 5 dB 20 Hz–10 kHz)
- Useful range1
- 10 Hz to 100 kHz
Approximate sensitivity @100 kHz = -230 dB re: 1V/µPa - Nominal capacitance
- 15 nF
Integrated Preamplifier with Plug-in Power (H3dM)
The following specifications are based on typical response when using the H3dM with typical microphone plug-in power:- Sensitivity
- -182 dB re: 1V/µPa (+/- 5 dB 20 Hz–10 kHz)
- Useful range1
- 10 Hz to 100 kHz
Approximate sensitivity @100 kHz = -220 dB re: 1V/µPa - Output impedance
- 1.1 kΩ (depends on mic preamp)
- Power
- 0.7mA at 2 V compliance voltage
- Notes: there is no standard for plug-in power, performance can vary significantly. We've found this configuration to be most common: a compliance voltage of 2.5 V and bias resistor of 1.1 kΩ (two channels at 2.2 kΩ each, 2.2 mA.
Integrated Preamplifier with Phantom Power (H3dX)
The following specifications are based on typical response when using the H3dX with 48V phantom power:- Sensitivity
- -176 dB re: 1V/µPa (+/- 5 dB 20 Hz–10 kHz)
- Useful range1
- 10 Hz to 100 kHz
Approximate sensitivity @100 kHz = -220 dB re: 1V/µPa - Output impedance
- 6.8 kΩ (typical)
- Power
- 1.2 mA (typical)
1 Please note that we have specified a very wide useful range for this hydrophone because they are often used for simple detection and timing applications with high-amplitude ultrasound devices, such as acoustic beacons and anti-fouling systems. Take special note that sensitivity is substantially reduced at high frequencies. Note the linear range in the sensitivity specification. If needing a broadband hydrophone, consider the S1.
Shared
- Polar response
- Omnidirectional (<10 kHz)
- Operating depth
- <80 meters
- Operating temperature
- -10 to 65 °C
- Dimensions
- 17 mm × 32 mm (cable and output plug excluded)
- Mass
- 10 grams
- Specific gravity
- 1.3
- Cable
- 4.5 mm OD low-noise cable with tough urethane jacket